Floor elements

Insulation roll

Ready for use heat and impact sound insulation roll from quality-controlled polystyrene foam EPS 045 DES sm according to DIN EN 13163. Covered by
tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 4 kPa
Thermal conductivity: 0.045 W / (m · K)

Insulation roll

Insulation roll

Ready for use heat and impact sound insulation roll from quality-controlled polystyrene foam EPS 045 DES sm according to DIN EN 13163. Covered by
tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 4 kPa
Thermal conductivity: 0.045 W / (m · K)

Insulation sheet

Insulation sheet

Ready for use heat and impact sound insulation sheet from quality-controlled polystyrene foam EPS 045 DES sm according to DIN EN 13163. Covered by
tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 4 kPa
Thermal conductivity: 0.045 W / (m · K)

Insulation roll

Insulation roll

Ready for use heat and impact sound insulation roll from quality-controlled polystyrene foam EPS 035 DES sg according to DIN EN 13163. Covered by
tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 10 kPa
Thermal conductivity: 0.035 W / (m · K)

Insulation sheet

Insulation sheet

Ready for use heat and impact sound insulation sheet from quality-controlled polystyrene foam EPS 035 DES sg according to DIN EN 13163. Covered by
tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 10 kPa
Thermal conductivity: 0.035 W / (m · K)

Insulation roll

Insulation roll

Ready for use heat and impact sound insulation roll from quality-controlled polystyrene foam EPS 040 DES sg according to DIN EN 13163. Covered by
tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 5 kPa
Thermal conductivity: 0.040 W / (m · K)

Insulation sheet

Insulation sheet

Ready for use heat and impact sound insulation sheet from quality-controlled polystyrene foam EPS 040 DES sg according to DIN EN 13163. Covered by
tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 5 kPa
Thermal conductivity: 0.040 W / (m · K)

Insulation sheet

Insulation sheet

Ready for use heat insulation sheet from quality-controlled hard polystyrene foam EPS 040 DEO dm according to DIN EN 13163. Covered by tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015. For increased working loads without impact sound insulation demands.

Pressure load at a 10 % compression: 100 kPa
Pressure load at a 2 % compression: 30 kPa
Thermal conductivity: 0.040 W / (m · K)

Insulation sheet

Insulation sheet

Ready for use heat insulation sheet from quality-controlled hard polystyrene foam EPS 035 DEO dh according to DIN EN 13163. Covered by tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015. For increased working loads without impact sound insulation demands.

Pressure load at a 10 % compression: 150 kPa
Pressure load at a 2 % compression: 45 kPa
Thermal conductivity: 0.035 W / (m · K)

Insulation roll

Insulation roll

Ready for use heat and impact sound insulation roll from quality-controlled Neopor® EPS 032 DES sg according to DIN EN 13163. Covered by tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 5 kPa
Thermal conductivity: 0.032 W / (m · K)

Insulation sheet

Insulation sheet

Ready for use heat and impact sound insulation sheet from quality-controlled Neopor® EPS 032 DES sg according to DIN EN 13163. Covered by tear- and waterproof overlapping tissue foil with printed grid according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Maximum load: ≤ 5 kPa
Thermal conductivity: 0.032 W / (m · K)

Hollow section panel

Hollow section panel

Hollow section panel from polypropylene to lay on already installed insulation. The panel can be used in combination with the self-adhesive clip rail or with clips to fix the pipe. Printed grid of 50 mm and multiples (pipe centers). Fire protection class B1.

Castellated panel NP 30-2

Castellated panel NP 30-2

Heat and impact sound insulation panel from hard/soft polystyrene foam EPS DES sg according to DIN EN 13163 with connective fold. With new polymeric flame retardant as of 01.01.2015. The upper overlapping polystyrene foil is tight against liquid screeds and screed mixing water according to DIN 18560 and DIN EN 1264.

The structure allows pipe spacing of 80 mm and multiples. Diagonal pipe laying directly on the castellated panel without accessories is possible.

Castellated panel NP 11

Castellated panel NP 11

Heat insulation panel from hard polystyrene foam EPS DEO dm according to DIN EN 13163. With new polymeric flame retardant as of 01.01.2015. The upper overlapping polystyrene foil connects the elements and is tight against liquid screeds and screed mixing water according to DIN 18560 and DIN EN 1264.

The structure allows pipe spacing of 80 mm and multiples. Diagonal pipe laying directly on the castellated panel without accessories is possible.

Fill and distribution sheet FVE NP 30-2

Fill and distribution sheet FVE NP 30-2

Fill and distribution sheet from quality-controlled polystyrene foam EPS 040 DES sg according to DIN EN 13163. The upper compound foil is tight against liquid screeds and screed mixing water according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Fill and distribution sheet FVE NP 11

Fill and distribution sheet FVE NP 11

Fill and distribution sheet made of quality-controlled polystyrene foam EPS 035 DES ds according to DIN EN 13163. The upper compound foil is tight against liquid screeds and screed mixing water according to DIN 18560 and DIN EN 1264. With new polymeric flame retardant as of 01.01.2015.

Connection module ÜM NP 30-2/NP 11

Connection module ÜM NP 30-2/NP 11

Connection module from polystyrene foil for castellated panels NP 30-2 and
NP 11. To be used in door and wall areas. Without heat and impact sound insulation.

Size/useful size: 1000x200 mm

Castellated panel NP 30-2 SD

Castellated panel NP 30-2 SD

Heat and impact sound insulation panel from polystyrene foam EPS DES sg according to DIN 13163. With new polymeric flame retardant as of 01.01.2015. The upper overlapping polystyrene foil connects the elements and is tight against liquid screeds and screed mixing water according to DIN 18560 and DIN EN 1264. The structure allows pipe spacing of 50 mm and multiples. Diagonal pipe laying directly on the castellated panel without accessories is possible.

Castellated panel NP 11 SD

Castellated panel NP 11 SD

Heat insulation panel from hard polystyrene foam EPS DEO dm according to DIN 13163. With new polymeric flame retardant as of 01.01.2015. The upper overlapping polystyrene foil connects the elements and is tight against liquid screeds and screed mixing water according to DIN 18560 and DIN EN 1264. The structure allows pipe spacing of 50 mm and multiples. Diagonal pipe laying directly on the castellated panel without accessories is possible.

Round PE sealing cord NP

Round PE sealing cord NP

Sealing cord from polyethylene to fix the foil of the insulation strip on castellated panels and castellated foils along the walls.

Diameter: 20 mm

Expansion strip NP

Expansion strip NP

Expansion strip for castellated panels and castellated foils, from polyethylene with self-adhesive base for secure separation of the screed fields.

Base Ø: 22 mm

Castellated foil FN 14-16

Castellated foil FN 14-16

Castellated foil without insulation for the laying of pipes on already installed insulation. To cover the insulation according to DIN 18560 and DIN EN 1264. The connection of the castellated foil is done by a push-button technique. The foil structure allows pipe spacing of 50 mm and multiples. Diagonal pipe laying directly on the castellated foil without accessories is possible.

Castellated foil as coil FNR 14-16

Castellated foil as coil FNR 14-16

Castellated foil as coil without insulation for the laying of pipes on already installed insulation. To cover the insulation according to DIN 18560 and DIN EN 1264. The connection of the castellated foil is done by a push-button
technique. The foil structure allows pipe spacing of 50 mm and multiples. Diagonal pipe laying directly on the castellated foil without accessories is possible.

Castellated foil FN 10

Castellated foil FN 10

Castellated foil without insulation for the laying of pipes on already installed insulation. To cover the insulation according to DIN 18560 and DIN EN 1264. The connection of the castellated foil is done by a push-button technique. The foil structure allows pipe spacing of 50 mm and multiples. Diagonal pipe laying directly on the castellated foil without accessories is possible.

Castellated foil as coil FNR 10

Castellated foil as coil FNR 10

Castellated foil as coil without insulation for the laying of pipes on already installed insulation. To cover the insulation according to DIN 18560 and DIN EN 1264. The connection of the castellated
foil is done by a push-button technique. The foil structure allows pipe spacing of 50 mm and multiples. Diagonal pipe laying directly on the castellated foil without accessories is possible.

Glue pad

Glue pad

Self-adhesive glue pad from polybutene for additional fixing of castellated foil systems.

Fixing bridge

Fixing bridge

Fixing bridge to hold the pipes down in the castellated panel or to hold the edges down. Also to be used for the connection of butt-jointed system panels.